Induction Cooktops
Induction cooktops require a dedicated circuit from the switchboard, correctly sized for the cooktop's load rating. Some models connect via a plug and socket; others are hardwired directly to the fixed wiring. Most 60–90 cm induction cooktops draw 7–10 kW and require a 32–40 amp circuit.
Where you are replacing a gas cooktop with induction, a new circuit is always required — gas cooking does not use a dedicated electrical circuit. We run the circuit, fit a suitable isolation switch and install the appliance, and issue the Certificate of Electrical Safety.
Electric Ovens
Electric ovens typically require a dedicated circuit. Most single ovens draw 2-3.5 kW; double ovens draw more. Where an oven is being replaced like-for-like, the existing circuit may be reused provided it is in good condition and correctly sized for the new appliance.
Where the new oven has different electrical requirements, a larger load, a different connection type, we assess the existing circuit and advise before installation.
Gas to Electric Conversions
Converting from gas cooking to full induction requires running new circuits for both the cooktop and the oven if neither currently has an electrical connection. We assess your switchboard capacity, run the required circuits, and make the connections. The gas isolation and removal of the gas fitting is a plumber's scope, we handle the electrical side.
Switchboard Capacity
Kitchen appliances are among the highest-load items in a home. Adding induction cooking to a property that previously had gas can add 10-15 kW of additional load. We check your switchboard capacity as part of every kitchen electrical quote, if an upgrade is required, we tell you upfront.
Frequently Asked
No. Hardwired connection of a fixed appliance is notifiable electrical work under Victorian law and must be performed by a licensed electrician.
Depends on the circuit size and the cooktop's load rating. We check the existing circuit against the new appliance specification before installation. If the circuit is undersized, we replace it.
Not always, if the existing circuit is correctly rated and in good condition, and the new appliance has the same or lower load, we can reuse the circuit. We confirm this on inspection.
A legal document issued by a licensed electrician confirming that notifiable electrical work has been completed to the required standard. It is issued for the work and a copy is provided to you as the property owner.